How we calculate
Every figure on this site comes from the same calculation code, so a page can never disagree with the calculators. Data last reviewed November 25, 2026.
1. Sauna heater size
- Room volume is inside length × width × ceiling height.
- Glass and bare surfaces. Each square foot of glass, tile, stone or concrete adds 3.94 cubic feet. This is Harvia's published rule of 1.2 m³ for each square metre of uninsulated surface.
- Uninsulated log walls multiply the total by 1.5, also from Harvia.
- Power needed is 1 kW for every 50 cubic feet, the baseline North American heater charts use. The European rule of 1 kW per cubic metre is more conservative and gives a larger heater.
- The heater shown is the smallest standard size at or above that figure: 3, 4.5, 6, 8, 9, 10.5, 12 kW. We flag rooms that sit above 45 cubic feet per kW, where the next size up heats faster.
Each heater maker publishes a room-volume range for each model and they differ. Treat the result as the size class to shop in, then check the range for the model you choose.
2. Sauna circuit
- Amps are watts ÷ 240.
- The 125% figure is the standard allowance for a continuous load.
- Breaker and wire sizes are those heater makers publish for each power. Where published figures differ we show the range. The 12 kW row is worked out from the 125% rule because we found no consistent published figure.
3. Sauna running cost
- Heat-up: heater power × heat-up time, at full power.
- In use: heater power × session time × 50%, because the thermostat cycles the elements. The range shown uses 40% to 65%.
- Infrared cabins use the nameplate watts at 85% while in use. The wattages by cabin size are typical figures; enter the nameplate value if you have it.
- Default electricity prices: U.S. average residential price forecast for 2026, about 18 cents per kWh (EIA Short-Term Energy Outlook). Canadian average residential price, about 17 cents per kWh. Provinces range from about 8 to more than 30 cents (Canada Energy Regulator). Enter your own.
4. Cold plunge chiller size
- Heat to remove is gallons × 8.34 lb × the temperature drop in °F, in BTU.
- Heat leaking in is U × surface area × (air temperature − water temperature). Surface area is estimated from volume as 6.5 × (cubic feet)2/3. U is 1.5 for "no lid, no insulation", 1.1 for "lid on, bare walls", 0.2 for "insulated, with a lid", in BTU per hour per square foot per °F.
- Cooling needed is the heat to remove ÷ the cool-down time you choose, plus the heat leaking in.
- Chiller classes use 2,500 BTU/h for 1/4 HP, 3,400 BTU/h for 1/3 HP, 5,000 BTU/h for 1/2 HP, 7,000 BTU/h for 3/4 HP, 9,300 BTU/h for 1 HP. Published ratings for the same horsepower vary widely, so the cool-down range uses a low and high figure for each class.
- Electricity is the heat leaking in ÷ a coefficient of performance of 2.5 (range 2 to 3.5).
The insulation values and the coefficient of performance are our engineering estimates, not manufacturer figures. They are the least certain numbers on the site.
5. Ice
- Each pound of ice absorbs 144 BTU melting, then 1 BTU for each °F it warms above 32°F.
- Between plunges, water without a chiller warms toward the air temperature following Newton's law of cooling, using the same heat-leak figures as above.
- Default ice price is $0.30 a pound in the United States and C$0.40 in Canada. Chiller prices are typical U.S. ranges by size, converted at 1.38 for Canada. Both are assumptions to replace with your own.
6. What the calculators leave out
- Wood-burning and gas sauna heaters.
- Electrical code load calculations for your panel. Your electrician's calculation governs.
- Chiller capacity falling as the water gets colder. Check the rating at your target temperature.
- Sun on the tub, wind, and heat from your body. These add to the load on hot days.
- Health guidance of any kind.
Sources
- Harvia: choosing heater power
- HUUM: sizing a sauna heater
- HUUM heater sizing sheet (breaker and wire by model)
- Leisurecraft cabin sauna heater sizing guidelines
- Hydrobuilder: water chiller sizing by BTU per hour
- Peak Primal Wellness: 1/4, 1/2 and 1 HP chiller capacities
- EIA Short-Term Energy Outlook: electricity
- Canada Energy Regulator: residential electricity prices by province
Questions or corrections: get in touch.