What size heater for a 5x5 sauna?
A 4.5 kW heater. A 5 by 5 foot room with a 7 foot ceiling holds 175 cubic feet, and with a small window in the door it needs 3.8 kW.
| 5 × 5 ft room | Volume to heat | Power needed | Heater |
|---|---|---|---|
| Solid wood door | 175 cu ft | 3.5 kW | 4.5 kW |
| Wood door with a window | 191 cu ft | 3.8 kW | 4.5 kW |
| All-glass door | 230 cu ft | 4.6 kW | 6 kW |
| 8 ft ceiling, door with a window | 216 cu ft | 4.3 kW | 4.5 kW |
Rule: 1 kW for every 50 cubic feet, plus 3.94 cubic feet for each square foot of glass. What a 4.5 kW heater needs from your panel.
Adjust it for your room
Your sauna needs a
4.5 kW heater
It has 191 cu ft to heat, counting glass and bare surfaces, which takes 3.8 kW.
- 3
- 4.5
- 6
- 8
- 9
- 10.5
- 12
Electrical
| Draw at 240 Vsingle phase, hardwired, on its own circuit | 18.8 A |
|---|---|
| 125% for a continuous loadthe figure electricians size the circuit from | 23.4 A |
| Breakerwhat heater makers publish for this size | 30 A, double-pole |
| Copper wireheavier for runs over about 50 ft | 10 AWG |
Heater makers publish their own breaker and wire sizes and they differ between models. The installation manual for your heater, and your electrician, decide. What the wiring involves.
What it costs to run
| Electricity per session40 min heat-up, then 30 min in use | 4.1 kWh |
|---|---|
| Cost per sessionlikely range $0.70 to $0.80 | $0.74 |
| Cost per month3 sessions a week at $0.18 per kWh | $9.65 |
| Cost per year | $116 |
How the size was worked out
| Room volume5 × 5 × 7 ft, or 5.0 m³ | 175 cu ft |
|---|---|
| Allowance for glass and bare surfaces4 sq ft × 3.94 cu ft | + 16 cu ft |
| Volume the heater must cover5.4 m³ | 191 cu ft |
| Heater power needed1 kW for every 50 cu ft | 3.8 kW |
4.5 kW heater. About $0.74 a session.See the working
Common questions
How many kW does a 5 x 5 sauna need?
A 5 by 5 foot sauna with a 7 foot ceiling holds 175 cubic feet and needs 3.5 kW with a solid door, so a 4.5 kW heater. With an all-glass door it needs 4.6 kW, a 6 kW heater.
What breaker does a 5 x 5 sauna need?
The 4.5 kW heater this room takes draws 18.8 amps at 240 volts. Makers publish a 30 A double-pole breaker and 10 AWG copper wire for that size.
How much does a 5 x 5 sauna cost to run?
About $0.74 a session at $0.18 per kWh: 4.1 kWh for a 40 minute heat-up and 30 minutes of use. Three sessions a week comes to about $9.65 a month.