9 kW sauna heater
A 9 kW electric heater covers a sauna of up to about 450 cubic feet and draws 37.5 amps at 240 volts.
Room size
| Largest room1 kW for every 50 cu ft | 450 cu ft |
|---|---|
| Comfortable up toheats faster, better outdoors in the cold | 405 cu ft |
| In metric | 12.7 m³ |
None of the common room sizes with a 7 foot ceiling land on this heater exactly. Use the planner with your own dimensions.
Breaker and wire
| Draw at 240 V, single phase | 37.5 A |
|---|---|
| With 125% for a continuous load | 46.9 A |
| Breaker, double-poleas published by heater makers | 50 A |
| Copper wireheavier for runs over about 50 ft | 8 AWG or 6 AWG |
| Output on a 208 V supply | 6.8 kW |
The heater is hardwired on its own circuit. Published breaker sizes differ between models of the same power, so the installation manual decides. On a 208 volt supply, found in some condos and commercial buildings, the same heater gives about three quarters of its rated heat. More on the wiring.
Running cost
A 40 minute heat-up at full power, then 30 minutes of use with the heater cycling about half the time, uses 8.3 kWh.
| Electricity price | Per session | Per month, 3 a week |
|---|---|---|
| $0.12 per kWh | $0.99 | $12.87 |
| $0.18 per kWh | $1.48 | $19.30 |
| $0.30 per kWh | $2.48 | $32.18 |
Common questions
What size room does a 9 kW sauna heater cover?
Up to about 450 cubic feet, at 1 kW for every 50 cubic feet. It is most comfortable below 405 cubic feet. Glass and bare masonry count as extra volume.
What size breaker does a 9 kW sauna heater need?
It draws 37.5 amps at 240 volts, and 46.9 amps once the 125% allowance for a continuous load is added. Heater makers publish a 50 A double-pole breaker with 8 AWG or 6 AWG copper wire.
How much does a 9 kW sauna heater cost to run?
About 8.3 kWh for a 40 minute heat-up and a 30 minute session. That is $1.48 at $0.18 per kWh.
Check the size against your own room, glass and ceiling height.
Open the planner